Node Home

Within a given link, there may be one or more linkset nodes. Each linkset encompasses all the traffic between two endpoints in a link.

For slave link types of master/slave protocols (for example the MODBUS_SLAVE_RTU), the link may be representing one or more Modbus slaves within the SHIPEngine environment. Even though the protocol is running on a single physical communications channel (e.g. UART0), each linkset within the link can act as one of a number of independent virtual slaves.

For master link types of of master/slave protocols (for example MODBUS_MASTER_ASCII) you may want to address multiple slaves on the channel. Each slave would be identified by a linkset with the slave ID set appropriately.

Parent Nodes

The following nodes are permitted to hold this node:

Child Nodes

The following nodes are permitted to exist within this node:

Properties

Property Data Type Description
Must specify a property (e.g. visible)[[SHIP:Property:name:{{{2}}}|{{{2}}}]] name A unique linkset name
Must specify a property (e.g. visible)[[SHIP:Property:id:{{{2}}}|{{{2}}}]] Byte Some protocols require the endpoint to have an ID number assigned
Must specify a property (e.g. visible)[[SHIP:Property:refresh:{{{2}}}|{{{2}}}]]* Boolean Set true to start a polling cycle on master/slave protocols; goes false when poll complete
Must specify a property (e.g. visible)[[SHIP:Property:enabled:{{{2}}}|{{{2}}}]]* Boolean Defaults to false; must be set true at runtime from a Sail script to enable the link

*available at SHIPEngine run time only and cannot be set in SHIPTide. Use a Sail script at shiplaunch time if this property needs to be set when the GUI starts to run.

Examples

Adding two linksets to the example in link reference:

Example link with two linksets

In this example, our GUI is acting as a Modbus Slave attached to UART0, potentially one of many on the communications channel. This physical channel could be, for instance, a multi-drop RS485 network with many slaves of which our SIM is only one. Our GUI, because it has the two linksets at ID #1 and #13 created, will respond as if it were two of those slaves on the network.